Search results
Results From The WOW.Com Content Network
Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.
The ductwork airtightness level is the airflow rate through ductwork leakages divided by the ductwork area. It is recommended to test at least 10% and 10 m 2 of the duct surface including all duct types and a variety of sizes and components. The ductwork surface area is estimated according to EN 14239. [11]
List of construction trades. The following is a list of trades in construction . Bell hanger installs mechanical and electrical bell systems. Boilermaker, works in nuclear, oil and gas industry, shipyards, refineries, and chemical plants, on boilers, pressure vessels, and similar equipment. Carpenter, a craftsperson who performs carpentry ...
Fire damper. Interior of German mechanical fire damper inside of a galvanised steel duct. Fire dampers (or fire shutters) are passive fire protection products used in heating, ventilation, and air conditioning (HVAC) ducts to prevent and isolate the spread of fire inside the ductwork through fire-resistance rated walls and floors. [1]
Ducts are conduits or passages used in heating, ventilation, and air conditioning (HVAC) to deliver and remove air. The needed airflows include, for example, supply air, return air, and exhaust air. [ 1] Ducts commonly also deliver ventilation air as part of the supply air. As such, air ducts are one method of ensuring acceptable indoor air ...
Ventilation (architecture) An ab anbar (water reservoir) with double domes and windcatchers (openings near the top of the towers) in the central desert city of Naeen, Iran. Windcatchers are a form of natural ventilation. [ 1] Ventilation is the intentional introduction of outdoor air into a space. Ventilation is mainly used to control indoor ...
The mixing plenum normally combines two air streams, and includes for three sets of dampers: one for the fresh air, one for the exhaust air, and a mixing damper between the two air streams. [2] The mix of fresh air and recirculated air can thus be adjusted to suit the needs of the building's occupants. Most systems will use motorized dampers to ...
Mechanical systems drawing is a type of technical drawing that shows information about heating, ventilating, air conditioning and transportation around the building (Elevators or Lifts and Escalator). [1] It is a powerful tool that helps analyze complex systems. These drawings are often a set of detailed drawings used for construction projects ...